ANTIMICROBIAL - Gram Negative - Gram Positive Bacterial Challenge Test of ION-ZCM1

Abstract

Author: Laboratorio de Control - ARJ - Principle Investigator QFB Rocio Guadalupe Gonzales Guerrero (2020).

Methods: The test was carried out based on the Mexican Official Standard NMX-BB-040-SCFI-1999 for the determination of antimicrobial activity in germicide products.
Disinfectant activity by 30-second challenge tests for Gram-Negative Escherichia coli (ATCC 11229), Gram-Positive Staphylococcus aureus (ATCC 6538), and Gram-Negative Pseudomonas aeruginosa (ATCC 15442)

Results: Initial viable account 120 000 000 (UFC/ml) vs Final viable account 0 (UFC/ml).

Conclusions: During the analysis, a 100% percent reduction of Gram-Negative Escherichia coli (ATCC 11229), Gram-Positive Staphylococcus aureus (ATCC 6538), and Gram-Negative Pseudomonas aeruginosa (ATCC 15442) was determined after 30 seconds of contact with the product ION-ZCM1.

 

Full Study Spanish Full Study English
Location
Ion Biotechnology México S.A. de C.V.
Plaza Marina Local D24
Puerto Vallarta
Jalisco, Mexico
Hours
Mon - Fri: 9:00 am to 6:00 pm CST.
Saturday - Sunday: Closed.
Phone Numbers
MX: +52 (322) 221-1057
USA: +1 (866) 333-7689
Report an adverse event
© 2024 Copyright - Ion Gel ZCM-25® 2+Cations® All Rights Reserved Ion Biotechnology México, S.A. de C.V.
cross